美國(guó)NDT James C-CL-3000 Chlorimeter混凝土氯離子含量測(cè)定儀 The Chlorimeter Chloride Test System A field kit for the determination of chloride ion content in concrete, fresh cement, masonry, most other construction materials, and water. Applications Service life prediction Corrosion analysis Features & Benefits Fast - Results within minutes at the site. Economical - Low cost per sample compared to laboratory testing. Accurate - Results are comparable to laboratory testing. Covers wide range from 0.002% to 2% chloride by weight Internal Memory to store readings for later upload to a PC via USB. Digital display for direct reading of percentage of chloride by weight. Conforms to AASHTO-T- 260. Menu in English and Spanish. The Chlorimeter produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered. Technical The determination of the chloride ion concentration in concrete is essential in assessing the need for maintenance on, for example, bridge decks and parking structures. The test can also be used to ensure that materials used in new construction are free from potentially harmful chloride ion levels. With this method, the concentration of acid soluble chlorides is measured. In most cases, this is equivalent to total chloride concentration. A sample of powder is obtained by drilling and careful quartering. Then an accuray weighed 3 gr. (0.1 oz) sample is dissolved in 20 ml (0.67 fl. oz.) of extraction liquid which consists of a precise, measured concentration of acid. For sampling wet concrete a 3 gr. (0.1 oz.) sample of mortar (i.e. without coarse aggregate) is used. Typically for concrete, samples that are to be analyzed for chloride are obtained at various depths, thereby supplying the engineer with a chloride ion profile. The chloride ions react with the acid of the extraction liquid in an electrochemical reaction. An electrode, with integral temperature sensor, is inserted into the liquid and the electrochemical reaction measured. A uniquely designed instrument converts the voltage generated by the chloride concentration and sensor into a reading for the user. The instrument automatically applies the temperature correction and it shows the chloride concentration on a LCD display percentage by weight. The unit uses 4 'AA' batteries for power. The Chlorimeter can also store test results and upload them to PC via USB. Once the sample is obtained, test results can be determined and read in less than five minutes. These initial values give a valuable indicator of the current chloride concentration values. Accurate results are typically obtained after the sample has been in the extraction liquid for 24 hours. To avoid contamination, the electrode should be thoroughly washed with de-ionized water after each test. Replacement packs, containing twelve bottles of extraction liquid, each for one time use, are available. Five calibration liquids each with known concentrations are supplied with each pack. Bulk packs of one hundred extraction liquids are also available for larger testing jobs. Thecalibration liquids are used to establish the calibration curve, and to check that the system is functioning correctly. Calibration is not required for each use. The calibration liquids are colored to avoid confusion between them and with the extraction liquid. All equipment necessary to complete the chloride test is supplied in a standard size carrying case. Components C-CL 3700 | Chloride combination electrode with externally mounted temperature sensor, cable, and connectors. | C-CL 3020 | Battery powered, high impedance, electronic meter, with temperature compensation circuits and microprocessor for direct conversion to percentage of chloride. Uses four 'AA" size batteries. | C-CL 2012 | Optional pack of 12 jars each with 20 ml (0.67 fl. oz.) of extraction liquid and 5 jars of colored calibration liquid. | C-CL 1030 | Bottle of electrode wetting agent. | C-CL 2096 | Optional bulk pack of 100 jars extraction liquid and 20 jars of colored calibration liquid. |
美國(guó)NDT James C-CL-2000 Chlorimeter混凝土氯離子含量測(cè)定儀 這是一個(gè)能裝在手提箱內(nèi)的測(cè)量混凝土內(nèi)含氯量的試驗(yàn)室。 特 性 : 『 在工地現(xiàn)場(chǎng),能在幾分鐘內(nèi)快速測(cè)得混凝土的含氯量。 『 與試驗(yàn)室分析相比,費(fèi)用低廉。 『 與試驗(yàn)室試驗(yàn)相比,結(jié)果準(zhǔn)確。 『 環(huán)境溫度變化時(shí),儀器具有自動(dòng)補(bǔ)償功能。 『 含氯量以百分比和 ppm 表示,可直接讀數(shù)。 工作原理 : 『 混凝土內(nèi)含氯量十分重要,橋面及停車場(chǎng)等混凝土內(nèi)的含氯量的評(píng)估尤為關(guān)鍵,因?yàn)檫@直接關(guān)系到確定該構(gòu)筑物是否需要維護(hù)及確定其維護(hù)范圍的大小?;炷羶?nèi)增添新材料時(shí)也能對(duì)其含氯量進(jìn)行分析,從而避免混凝土結(jié)構(gòu)受到過(guò)高含氯量的損害。 用這種方法可以測(cè)出混凝土內(nèi)酸溶性氯化物的含量,其單位為重量百分比和 ppm 濃度。在大多數(shù)情況下,上述數(shù)值與總含氯量是相當(dāng)?shù)??!?在混凝土構(gòu)筑物上,用鉆孔法取樣,將鉆出的 3 克混凝土粉溶入 20 毫升的酸性萃取液內(nèi),萃取液的濃度是經(jīng)過(guò)精確標(biāo)定的?;炷林械穆入x子與萃取液中的酸發(fā)生電化學(xué)反應(yīng)。 『 將一個(gè)帶溫度傳感器的電極,插入上述萃取液中,對(duì)電化學(xué)反應(yīng)進(jìn)行測(cè)量,經(jīng)特殊設(shè)計(jì)的儀器能把氯化物反應(yīng)所產(chǎn)生的電壓經(jīng)溫度修正后轉(zhuǎn)換為含氯量的濃度,直接在液晶顯示器上顯示。 『 一旦獲取混凝土粉樣品,用該儀器在幾分鐘之內(nèi)即可得到準(zhǔn)確結(jié)果。 『 為避免污物影響測(cè)量精度,每次測(cè)試前應(yīng)用蒸餾水對(duì)電極加以*清洗。 『 儀器帶有一盒萃取液,內(nèi)裝 12 瓶,每次測(cè)試用一瓶。盒內(nèi)還有兩瓶校準(zhǔn)液,每瓶校準(zhǔn)液的濃度已預(yù)先標(biāo)定,其用途是使操作者能校準(zhǔn)儀器的精度。為避免在使用中發(fā)生混淆,校準(zhǔn)液有兩種顏色,一瓶是紅色的,一瓶是藍(lán)色的。 『 所有與含氯量有關(guān)的東西都裝在一個(gè)手提箱內(nèi),攜帶十分方便。 C-CL-2000 混凝土含氯量測(cè)定儀由下述部分組成: C-CL-3700 帶有溫度補(bǔ)償傳感器的氯化物測(cè)量電極 C-CL-2020 由電池供電用來(lái)直接顯示氯的百分含量的帶有溫度補(bǔ)償電路和微處理器的高阻抗讀數(shù)器 C-CL-2012 備件盒。內(nèi)有塑料瓶裝萃取液 12 瓶,每瓶 20ml ,盒內(nèi)還有 5 瓶有顏色的校準(zhǔn)液 C-CL-1030 電極浸潤(rùn)劑瓶 以上是美國(guó)NDT James C-CL-3000 Chlorimeter混凝土氯離子含量測(cè)定儀的詳細(xì)信息,如果您對(duì)美國(guó)NDT James C-CL-3000 Chlorimeter混凝土氯離子含量測(cè)定儀價(jià)格、廠家、品牌、型號(hào)、圖片、規(guī)范、規(guī)格、原理有疑問(wèn),或需要詳細(xì)報(bào)價(jià)單、宣傳冊(cè)、中英文產(chǎn)品說(shuō)明書,請(qǐng)點(diǎn)擊我公司 美國(guó)NDT James相關(guān)產(chǎn)品介紹: 美國(guó)NDT James T-HT-1000 Humiditest混凝土鉆孔濕度測(cè)試儀 美國(guó)NDT James T-C-10 T-C-20 Cementometer微波水泥含水率測(cè)試儀 美國(guó)NDT James T-S-30 Aquaprobe微波土壤含水率測(cè)試儀 美國(guó)NDT James T-M-170 Aquameter混凝土含水率測(cè)試儀 美國(guó)NDT James T-T-90 Trident插針式微波骨料含水率測(cè)試儀 美國(guó)NDT James I-CB-6000 Carbo Detect混凝土碳化深度酸堿指示劑 美國(guó)NDT James I-AS-3000 ASR-Detect混凝土堿骨料反應(yīng)測(cè)試儀 美國(guó)NDT James A-AB-1200 A-AV-1300 A-AA-1100 Air Meters混凝土含氣量測(cè)試儀 美國(guó)NDT JAMES Z-WP-1000 Windsor Probe混凝土強(qiáng)度槍擊檢測(cè)儀 美國(guó)NDT JAMES W-P-2000 Windsor Pin混凝土強(qiáng)度檢測(cè)儀 美國(guó)NDT JAMES R-HR-8000 Mini R-Meter鋼筋定位儀 美國(guó)NDT JAMES P-C-7300 Bond Test MK III粘結(jié)強(qiáng)度測(cè)試儀 美國(guó)NDT JAMES P-C-728 P-C-729 Anchor錨栓測(cè)試儀 美國(guó)NDT JAMES M-M-3056 Maturity Meter混凝土成熟度測(cè)試儀 美國(guó)NDT JAMES Datascan MK II鋼筋混凝****達(dá) 美國(guó)NDT James C-P-6000 C-P-6050 Porosiscope混凝土滲氣滲水性測(cè)試儀 美國(guó)NDT James C-CM-4000 Cor-Map鋼筋銹蝕檢測(cè)儀 美國(guó)NDT James C-CL-3000 Chlorimeter混凝土氯離子含量測(cè)定儀 美國(guó)NDT James W-M-350 W-M-250 Rebound Hamme機(jī)械回彈儀 美國(guó)NDT James W-D-2000 Rebound Hamme數(shù)字回彈儀 美國(guó)NDT James V-E-1000 E-Meter MK II動(dòng)態(tài)彈性模量測(cè)試儀 美國(guó)NDT James V-V-100 Vu-Con沖擊回波測(cè)試儀 美國(guó)NDT JAMES V-C-400 V-Meter MK IV混凝土超聲波測(cè)試儀 美國(guó)NDT James C-CS-8000 C-CS-8300 Gecor 8鋼筋銹蝕程度測(cè)定儀 美國(guó)NDT James C-RM-8000 Ohmcorr混凝土電阻率測(cè)定儀 美國(guó)NDT James C-CM-5000 Cor-Map II大屏幕半電池電壓鋼筋銹蝕檢測(cè)儀 美國(guó)NDT JAMES R-C-400/450/475/410 Rebarscope鋼筋掃描儀 關(guān)鍵詞 :氯離子含量快速測(cè)定儀/氯離子含量測(cè)定儀/氯離子含量測(cè)試儀/混凝土氯離子含量測(cè)定儀/混凝土氯離子含量快速測(cè)定儀 |